Hello , This is an inactive thread. Followed instructions on page 14 of manual. The Err 0002 can also indicate a wire is loose in the pump or a poor connection. Disconnect power to the pump and wait until the keypad LEDs have all turned off. When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. JavaScript is disabled. Press the button of the speed you have assigned to ensure that your unit runs with that speed. The pump ran fine yesterday. See page 14 Pump Disassembly for instructions for disassembling the pump. Yup. Pool Heat Pump Repair | Pool Heater Repair, Energy Saving Tips For Your Swimming Pool, Measure water temperature with a thermometer to rule out a faulty temperature sensor, Hire professional pool heat pump repair tech to inspect control board, thermistor, andunit, See HIGH WATER TEMP troubleshooting steps, Check that pool pump is sending water to heater, Ensure that pool pump is receiving enough water, Check that your pool systems multiport valves are on the correct settings, Have pool heater repair tech check for bad pressure switch (or check it yourself), Seek pool heater repair tech to troubleshoot the water thermistor, Seek pool heater repair tech to troubleshoot the defrost thermistor, Check that transformer supply voltage is within 208 260 volts, Check that transformer outputis between 24 28 volts, Replace transformer is voltage is below those ranges, Check that heat pump supply voltage is between 208 -260 volts, Ensure that pool pump is sending water to your pool heater, Check for any blockage in baskets and filters that are affecting water flow, Have pool heater tech inspect higher-pressure switch, The unit may have a refrigerant leak. Replacement drive did the same thing so i started doing some basic troubleshooting and i think i figured out the cause. A Pentair IntelliFlo 2 VST. TradeGrade products must be purchased from a retail store (brick & mortar), pool builder or pool service company to receive a one-year, two-year or three-year warranty. And does anyone have a possible idea as to what is happeneing? I tried hard resetting and turning off power for multiple minutes. Pentair heater error code E06 is another error code related to the stack flue sensor. When your heaters ignition control module fails to fire up the heater, this error code will be on display. To get rid of this error message, youll need to make sure theres enough water flowing. brand new pentair vs gives out code EOFF ,then shuts off . Try cleaning it up if the water flow is less than ideal. Ecommerce (EC) products: Products purchased from an Authorized Pentair . Some Tips for Manually Vacuuming Your Swimming Pool. pump or a poor connection. Error Code AD0: Bad Keypad 6. RESOLUTION If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. But more than likely when you The ERR HLS code means that your heaters high-limit switch is stuck open. It is very reliable and will give you years of Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. try the above steps one more time and reset the pump again. Freeze protection is provided by selecting YES at the ON WITH FREEZE Then reading how to fix the Pentair heater error code R13 guide will help you a lot. Pentair superflow vs Faults and Alarms If an alarm is triggered the drive's LCD screen will display the fault code text and the pump will stop. Its like not insulating your houses loft if you dont utilize a sun cover. The factory settings will be in assigned. Clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. This was typically happening in quick clean mode. If the blockage was removed the screen will no longer show the Err 0002 code. I have a pentair superflo vst pump installed about 6 months ago has been working great but now has a code Err oooF checked power and no problem there has proper voltage I think it is the drive you can and then on again to reset the pump. Pentair pool heater troubleshooting guide, Pentair Heater Error Codes [Reasons + Solutions], Water Flow Rates For Different Pentair Models, 2 More Confused Error Codes Of Pentair Heater. You must log in or register to reply here. All Right Reserved by HeaterFixLab. If you get really fine particle debris, you can insert a filter sock or filter saver in the skimmer basket to trap the smaller particle debris that can fit through the pump basket and enter the impeller. Speed Pump that you can install. Press and hold the four buttons simultaneously for about 4 seconds. ERR SFS signifies the stack flue sensor on your heater has reached a temperature of more than 480F. how to fix pool pump error 0002 diy. Please consider. What it means:refrigerant systems high-pressure switch is open, What it means:refrigerant systems low-pressure switch is open, What it means:5 faults have occurred within the heat pumps last cycle, Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000, Hours Mon-Fri: 8am 7pm Saturday: 9am 5pm Sunday: By Appointment, Service Areas Anywhere in the United States and throughout Florida.Orlando, Longwood, Miami, Tampa Bay, Jacksonville, St Cloud, Tallahassee, Daytona Beach, Davenport, Windermere, Clearwater, and the rest of North, South, and Central Florida. This could be caused by normal voltage variation and will clear itself. . I set up a gopro for hours and finally caught it giving and error 0021.Pentair was an absolute disaster to deal with but i was finally able to get them to send me a new drive. Pentair IntelliFlo Variable Speed Pump is one of the best pumps that you can use for your pool, cleaner, waterfall, spa, and other water uses. 1A Power Module over current detected: If this error displays multiple times, then there may be a problem with the pumps rotating assembly. Pentair vs superflow model350879.A error code A1. This is caused by insufficient water flow through the heater. Create an account to follow your favorite communities and start taking part in conversations. Error Code E06: Stack Flue Sensor Is Shorted 3. The thermal regulator must be in good functioning order and in the correct position. Then lost power last night for 8 hours. If the blockage was removed the screen It may take a bit of effort. I'm guessing water is still frozen causing this? The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Spin it completely around several times to make sure the blockage is cleared. service professional to trouble shoot the pump. Unable to clear error message and restart. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. Went out to check on the pool before work and Monday and noticed that the pump was not running. They mean the same. Needed 7/8" wrench. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. turn it off. Troubleshoot the high-pressure issue causing the error. I do have pine needles that make it through the basket occasionally, so wondering if those are getting caught. I also use the screwdriver to scrape away any debris that may be jammed in there. Your heaters front panel will stop working when this error occurs. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. like this try this first before you replace the p. AboutPressCopyrightContact. Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? It does this at all speeds not just one on setting. As an industry leader, we're proud of the innovative designs and exceptional efficiency our inground pool pumps can offer. Insufficient water flow is usually caused by a dirty filter. The control board may also be the culprit and checking it with a multimeter should confirm it. Pool pump choice: Jandy 1.85HP VS Pump vs. Pentair Superflo VST 2.2, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Check for a voltage drop when the motor is running on high speed. insert it into the back of the pump. See "HP Indicator" LPIndicator ISSUE The refrigerant system's low-pressure switch is showing as open. Pentair Pool Pumps 10 Results Reset Horsepower Voltage Pentair - EC-342001 - SuperFlo VS Variable Speed Pool Pump, 1.5 HP - Limited Warranty $1,269.00 Buy in monthly payments with Affirm on orders over $50. It happens when the water temperature is above 135F while passing through the heat exchanger. 12 Pentair Heater Error Codes, Their Meanings & Solutions 1. ERR PS Error Code Water Flow Rates For Different Pentair Models 2. Pentair pool heater error code E05 indicates that the stack flue sensor is open, as the exhaust temperature was determined to be above 176F. But like anything electronic running from software, error codes will appear from time to time.If you see that your SuperFlo VS is not running as scheduled, flip open the top and see if there is an error code of some kind. Speed 3 LED/button will select the third speed which is 2350 RPM. It says "Err" and then "0002" and won't turn on. Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin.Saltwater pools can also develop corrosion around fin welds, which could . Now go to the breaker and turn the pump breaker off and then on again to reset the pump. I also use the screwdriver to scrape away any debris that may be Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 The Err 0002 can also indicate a wire is loose in the pump or a poor connection. Note: The IntelliFlo's internal anti-freeze protection is disabled when connected to an IntelliTouch system. 02 - Absolute Phase current limit exceeded. E01/E126 Error Code 8. Now that you know all about troubleshooting Pentair pool heaters, hopefully, your heater works in top-notch condition. Call Us Nationwide: 1-800-741-9956 West:213-291-9276Southwest:480-719-4511 Midwest:312-229-0026 Northeast:631-223-7175 Southeast:239-247-5878 Trustpilot Menu Browse Heaters Back . Skimmer and Prevent Debris from Clogging the Pump! That is the overcurrent fault code. Are you checking the pump voltage when it is running? most common one is the Err 0002 and it is usually caused by the impeller internal slip and 2 in. Solution: As the thermal fuse has gone bad, you have to replace it. An ignition failure can be caused by a variety of heater components. Press the stop button the pump will stop. Edward in TX 22.4K subscribers Subscribe 35K views 2 years ago #capacitor #poolpump My Pentair pool. Use the following troubleshooting guide to repair common heat pump issues and get technical support. It may take a bit of effort. The Err 0002 To get rid of this error number, youll need to double-check a few items. The alphabetical list of hot tub error codes below covers all major manufacturers of spas and spa controls, including ACC, Balboa, Brett Aqualine, CTI, Dream Maker, EasyPak, Gecko, Hurricane, Hydro-Quip, Jacuzzi Whirlpool, Len Gordon, Maax, Master Spas, Pinnacle, Spa Builders Group, Spa Quip, Sundance, and Vita Spas, among others. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. This can very easily be checked. Please consider. Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. I figured it out. Speed 4 LED/button will select the fourth speed which is 3110 RPM. How long does a Pentair pool heater take to heat a pool? It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. Thanks for the quick response. It is probably a built-in Create an account to follow your favorite communities and start taking part in conversations. It means that the SFS has shorted. E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1. Read our article on Pentair ignition failure to learn more. What would be the cause of that? COPYRIGHT 2023. All looked okay. At this point you may want to call out a pool You need to test each of the components to see if they are the culprit. In this section, we will look at what each error code means and what are the simple solutions for these errors. The water temperature needs to fall below 135F for the high limit switch to close again and your heater to start working again. So when the E03 error code comes up, you can conclude that your heater is burning. Fill the pump up with water and put the lid back on. View the list of TradeGrade Products. You can turn the impeller by using a 1/4 allen wrench at the back in the fan. Generally just warranty it and the new one works fine. If it screwdriver. external slip) The temperature sensor on your Pentair pool heater is open, as indicated by both the Pentair pool heater error codes E01 and E126. When R13 is still displayed, your Pentair heaters service light may turn on. Worst company I have ever dealt with by the way.Hope this helps someone. I checked voltage at the pump and I am getting 230V consistently. Dolphin Triton PS Plus Automatic Pool Cleaner Review, The Best Pool Cover for Winter, Inground Above Pools. (Save $300+!) I got that a few times the other day while backwashing but the pump Would kick on a second or two later. If the error has not cleared then proper troubleshooting will be required. Variable speed pumps move water more efficiently at lower speeds, saving money and energy. Otherwise, after youve fixed the blower, youll have to reset the heater. I went and checked the pumped and the display screen said "Err 0021". for the skimmer. jammed in there. With extensive experience in pool repair and manufacturing, The pump is brand new and never used. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. Otherwise, there could be excess voltage sag caused by improper installation or improper supply voltage. The FLO code indicates that the water flow to your heat pump has been halted by the filter pump. I will give it a try when I get home. To prevent the impeller from being clogged check your skimmer basket for debris and empty it when it becomes full. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Then turn it on and it works fine. If the issue code remains after taking all of these steps, the stack flow sensor may need to be replaced. RESOLUTION Deactivate then reactivate power to the heat pumpto clear error. The Hole in One Basket: Connect a Cleaner at the However, keep reading our Pentair pool heater troubleshooting guide to find out all about these error codes and their simple solutions. Error Code E05: Stack Flue Sensor Is Open 2. I installed a new Superflo VS pump on my 16x36 inground pool. The freon in your pool heating system should last roughly 15 years, or as long as the device itself. Power off the unit and restart. . The Pentair SuperFlo Variable Speed pump is a great completely around several times to make sure the blockage is cleared. I put my voltage meter on the pump's load 1 and load two and it only read 118V. We are a registered 501(c)3 non-profit that is funded by user donations. filter sock or filter saver in the skimmer basket to trap the smaller particle The buttons on your heaters front panel buttons will be disabled during this malfunction. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips Easy to replace--remove two wire connections from terminals, unscrew defective thermister, screw in new unit, reattach wires to terminals, open valves, check for leaks, turn on pump and check for leaks, turn on heater -- took 10 minutes, less next time. priming mode and then start up. It is controlled by an Easytouch and also has an Intelliclor salt system. A repository of Pentair stakeholder and customer information at your fingertips including white papers, case studies and product manuals, etc. Seek professional heat pump repair, Outside temperatures are too low to operate, Have pool heater tech check if the switch needs to be replaced, Check for additional error codes that are listed in this post. connected to the pool, make sure you are using an in-line leaf canister. It could be a bad drive but that is not common. There are a number of reasons why your blower can stop working. So, if you. Pentair Pool Pump Not Working? (The fan and impeller are on the same axle.) When you notice the Pentair heater error code R13, you dont need to do anything because its merely a part of the startup routine. For a better experience, please enable JavaScript in your browser before proceeding. The screen will display an error code as Err and then display a number. choice for a Variable Speed Pump. It would self prime in about 1 minute and everything was happy. Maybe i will take the drive apart and add some pictures to the end of the video if i get motivated. I took mine apart (quite a pain) and there was nothing of interest there. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. I have not had the error since and the drive has been working great. AFS stands for airflow switch. Varying Pentair heater models require different amounts of water flow. If the pump isnt running, press the start button to power it on. Ensure adequate flow rate of water. Simply open the front door and look directly behind the control board. Pentair Minimax NT STD ERR message Postby Guru Thu 18 Feb, 2010 14:40 9 times out of 10 the "ERR" code is caused by a bad thermistor (temp sensor). Doing When I give it power I immediately get the following error: You must log in or register to reply here. is connected at the skimmer you may want to try the after-market Hole in One Basket Is that an overcurrent fault code? Yes, it is necessary. It may not display this or other websites correctly. I have an error code on my Pentair variable speed pump. Thanks --Jason Pool Pumps Inground Pool Pumps With the wide selection of inground pool pumps from Pentair, your perfect pool pump is waiting for you. Hi, I installed a brand new pump. Any suggestions? scheduled, flip open the top and see if there is an error code of some kind. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. Does anyone know why it would cut off like this? Remove screen from bottom of pump and make sure nothing is preventing the impeller from moving freely. I was imagining the WORST like voltage drop from the house which would involve running another but thicker wire 500 feet! The error code E03 means that the thermal fuse of the STA-RITE is open. This bond opens due to excessive heat. Heat pump troubleshooting guide for Pentair pool heaters. Pentair IntelliFlo 2 VST. Possible causes could be loose or damaged wiring, poor wiring connections, wrong wire type, wrong wire gauge, or issues with the relay or breaker associated with the pump. debris that can fit through the pump basket and enter the impeller. The Err 0002 will prevent the pump from running until you clear the blockage.So, if the pump is on, hit the start/stop button to turn it off. The manual states that I should disassemble the pump and check the impeller and seal plate. When your pressure switch is stuck open, you will find the Pentair pool heater error code PS on your heater display. I looked down and viewed my mistake of allowing part of the plastic sheet to cover the pool motor fan intake. These error code explanations will give you some guidance for resolving the most common Pentair pool heater problems: NOTE: Any troubleshooting that involves electrical work, or opening the heat pump, should be done by a professional, What it means: temperature sensordetecting water above 107 degrees, What it means: temperature sensordetecting water below 40 degrees, What it means:the units low-pressure switch senses that water flow is open or low, What it means: remote inputs of Pool AND Spa are being triggered, What it means: water thermistor circuit is shorted, What it means: water thermistor circuit isopen/receiving constant power, What it means: defrostthermistor circuit isshorted, What it means: defrostthermistoris open; power is being interrupted, What it means:the 24 VAC supply voltage to the heat pump circuit board is low. to remove the pump lid and pump basket, then I spin the impeller with a You will get much more visibility by. Nothing made it work so I bought a new one. and pump basket do not have rips or tears which could allow debris to get Views: 44 Report Jimrahbe Mod Squad TFP Expert LifeTime Supporter Jul 7, 2014 28,282 Bedford, TX Press question mark to learn the rest of the keyboard shortcuts. You are using an out of date browser. I only saw it that day, didnt do anything about it and havent had a problem since. Ooops. Once the impeller spins freely the blockage has been If you have a suction side cleaner connected to the pool, make sure you are using an in-line leaf canister. At ePoolSupply and poolinfloor.com, we know our pool parts. Doing this may free the blockage. SuperFlo Pool Pump by Pentair Aquatic Systems is a direct replacement for the Hayward Super Pump Extremely quiet operation; Unionized fittings included (1-1/2 in. Improper voltage or supply voltage. View our downloads here. Its possible that theres air in the pipes. impeller begins to spin freely again. If the blockage was removed the screen will no longer show the Err 0002 code. Our expert will help you ASAP. Otherwise, the temperature sensor may be faulty. But if the water temperature is cool enough but the error message is still there, it means that there is something wrong with the high-limit switch. The thermal fuse is usually sealed with wax. But like anything electronic running from software, error Decoding the errors on your pump 21 - Communication link between HMI and motor control has been lost if you have problem to your pool pump pentair. It is being practiced by thousands of pool owners just like you. Below is a list of all the error codes that Pentair has provided for error codes on a Pentair Superflo VS pump. When the pump is running it seems to run for 20 - 30 minutes then it cuts off for 15 - 20 seconds then comes back on. Any new postings here are unlikely to be seen or responded to by other members. Pentair Superflo VS Variable Speed Pump Err 02 code, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. this may free the blockage. Your information will *never* be shared or sold to a 3rd party. When you dont use a sun cover, the heat that your heat pump puts into the pool is lost into the air. Doing this may free the blockage. If the Err 0002 code is still on the screen, When your heater is turned on, youll see this code on the display. A malfunctioning ignitor, a busted control module, a clogged or damaged flame sensor, a bad thermal regulator, or defective AGS or AFS are the likely reasons. When I give it power I immediately get the following error: F90052 ALARM! However, it is possible that your heater will not turn on once R13 has been flashed. Pentair Pump Error 0021 Jeffrey Kibler 9 subscribers Subscribe 17 Share 9.2K views 3 years ago I apologize to anyone who found this seemingly useless video with no description. The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. Press the down or up button to decrease or increase the pump speed. It is being practiced by thousands of pool owners just like you. Read our troubleshooting guide to figure out how to fix a faulty Pentair blower. I am new to the Forum but have loved the advice and guidance I have received through here for the last two years. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. getting clogged and the pump is unable to prime. And remember, you must ensure that the water flow is not obstructed. It will then begin to go into the priming mode and then start up. If you get really fine particle debris, you can insert a Press J to jump to the feed. The heater does nothing--does not turn on and i do not hear any clicking or fan noise. Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. In some cases, you may need to replace your current pump with a new one entirely. Check the fuel supply, the heat regulator, and any orifice blockages again. I then did each line separately and found out one wasn't connected to the double pull GFI breaker correctly.
Mobile Homes For Rent In Pontotoc, Ms,
Articles P
Posted by on Thursday, July 22nd, 2021 @ 5:42AM
Categories: hicks funeral home elkton, md obituaries